Sign In | Join Free | My rc363.com |
|
All split core current transducer wholesalers & split core current transducer manufacturers come from members. We doesn't provide split core current transducer products or service, please contact them directly and verify their companies info carefully.
Total 8993 products from split core current transducer Manufactures & Suppliers |
|
![]() |
Brand Name:GFUVE Model Number:LZCK-55 Place of Origin:China ...Split Core Current Transformer Description LZCK series current transformers are applicable for AC power system 35kV and measurement of current of power supply equipment below 10KV also can be used or microcomputer protection. This type of current transformer employs imported silicon steel which with high permeability as magnetic material, has the charac teristics of Small magnetic circuit loss and can be split... |
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing |
![]() |
Brand Name:GFUVE Model Number:LZCK-55 Place of Origin:China ...split core current transformer 3000A LZCK series outdoor waterproof current transformers are applicable for AC power system 35kV and measurement of current of power supply equipment below 10KV also can be used for microcomputer protection. This type of current transformer employs imported silicon steel which with high permeability as magnetic material, has the characteristics of Small magnetic circuit loss and can be split... |
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing |
![]() |
Brand Name:Shenzhen Chuangyin Co.,Ltd. Model Number:CY-KCT01 Place of Origin:China We are manufacturer for Instrument Transformer. Current transformer Split Core Current Transformers Open type CT CY-KCT01 (50~300A) Description: *50~300A *Indoor *Dry type / Epoxy ... |
Shenzhen Chuangyin Co., Ltd.
Guangdong |
![]() |
Brand Name:Chuangyin Model Number:CY-LMCKX-10W Place of Origin:ShenZhen ... capability Current Overload Ability No need to cut off cable causing power outage Application: Static conversion for DC motor traction static ... |
Shenzhen Chuangyin Co., Ltd.
Guangdong |
![]() |
Brand Name:Chuangyin Model Number:CY-LMCKX-10W Place of Origin:China ... capability Current Overload Ability No need to cut off cable causing power outage Application: Static conversion for DC motor traction static ... |
Shenzhen Chuangyin Co., Ltd.
Guangdong |
![]() |
Brand Name:GFUVE Model Number:LZCG530-10 Place of Origin:BEIJING,CHINA GFUVE 100/5A Split Core Current Transformer LZCG530-10 Epoxy Resin Cast CT LZCK series resin split core current transformer is suitable forcurrent measurement and microcomputer protection of electrical equipment in 10KV and 35KV AC power system.It is ... |
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing |
![]() |
Brand Name:HEMEI Model Number:YB42 Place of Origin:China ... transformer is composed of a closed core and windings. Its primary winding has a few turns, which are stringed in the line where the current needs to be measured. Therefore, it often has all the current flowing through the line. The secondary winding has |
Hefei Hemei Electronics Technology Co., Ltd
Anhui |
![]() |
Brand Name:HEMEI Model Number:YB42 Place of Origin:China ... transformer is composed of a closed core and windings. Its primary winding has a few turns, which are stringed in the line where the current needs to be measured. Therefore, it often has all the current flowing through the line. The secondary winding has |
Hefei Hemei Electronics Technology Co., Ltd
Anhui |
![]() |
Place of Origin:Jiangsu, China (Mainland) Brand Name:chieful Model Number:CS2000EK2 ... AC,DC,pulsed and mixed current. Hall current sensors are widely applicable for acquisition and feeback control of current signals in the current monitoring,inverter,solar power management,current cabinet,DC motor drive and UPS servo control systems. Use: |
Nanjing Chieful Science & Technology Co., Ltd.
Jiangsu |
![]() |
Brand Name:Shinhom Model Number:SCTK681D Series Place of Origin:China SCTK681D Series CE RoHS Split Core Current Transformer , Low Voltage CT For Energy Monitoring Open-end current transformers are mainly used in power distribution system renovation projects, easy installation, no need to dismantle a bus, can also be live ... |
Shaanxi Shinhom Enterprise Co.,Ltd
Shaanxi |
![]() |
Brand Name:Acrel Model Number:AKH-0.66/K-Φ Place of Origin:China AKH-0.66/K ct split core current transformer Product feature The product has beautiful appearance, convenient installation and wiring, and is mainly used for power operation and maintenance and electricity ... |
Jiangsu Acrel Electrical Manufacturing Co., LTD.
Jiangsu |
![]() |
Brand Name:Chuangyin Model Number:CY-QCT03-46 Place of Origin:China 500A 50/60Hz Open type Split Core Current Transformer Smart Logger 1. Product Introduction: This type CT is designed for easy installation in tight spaces and environment without removing the main ... |
Shenzhen Chuangyin Co., Ltd.
Guangdong |
![]() |
Brand Name:Chuangyin Model Number:CY-QCT03-46 Place of Origin:China 500A 50/60Hz Open type Split Core Current Transformer Smart Logger 1. Product Introduction: This type CT is designed for easy installation in tight spaces and environment without removing the main ... |
Shenzhen Chuangyin Co., Ltd.
Guangdong |
![]() |
Place of Origin:Tianjin, China Brand Name:grewin Model Number:GWCTSB ... Rated Short-time thermal current (Ith) 20In Rated Dynamic current (Idyn) 2.5Ith Case Material UL flame retardant rating 94-V0 Highest Voltage for Equipment Um (rms) ... |
Tianjin Grewin Technology Co., Ltd
Tianjin |
![]() |
Brand Name:GFUVE Model Number:Q125 Place of Origin:China ... aluminum bus bar on-line detection. Features This product can be used for a current vector for the copper bar or the power aluminum bus bar on-line detection. holding wire diameter: 120mm*50mm Dimension: ... |
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing |
![]() |
Brand Name:GFUVE Model Number:LZCK-55 Place of Origin:China ...Split Core Current Transformer LZCK-55 Technical parameters Standards IEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; ANSI C57.13 Accuracy Class 0.5S, 0.5%, 1%, 3% Range of primary rated current 100-1000A Range of Rated load ≤10VA Rated frequency 50/60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA, 1S Rated continuous thermal current... |
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing |
![]() |
Place of Origin:Jiangsu, China (Mainland) Brand Name:chieful Model Number:CS1500K ...the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents.Hall current sensors are widely applicable for acquisition and feeback control of current signals in |
Nanjing Chieful Science & Technology Co., Ltd.
Jiangsu |
![]() |
Brand Name:GFUVE Model Number:FU - 32 Place of Origin:China ...Split Core Current Transformer CT With Accuracy 0.5% The CTs are ideal for quick and easy installation without disconnecting cables during installation. Multiple installation mechanisms provide stable and durable current measurement. Parameters Technical parameters Standards IEC/EN60044-1 & IEC61010-1 & IEC61869-2&ANSI C57.13 Ratio 400: 5 or 200:5 , customized Nominal input current(Primary current... |
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing |