Sign In | Join Free | My rc363.com |
|
All current transformer basics wholesalers & current transformer basics manufacturers come from members. We doesn't provide current transformer basics products or service, please contact them directly and verify their companies info carefully.
Total 12270 products from current transformer basics Manufactures & Suppliers |
|
![]() |
Brand Name:Shinhom Model Number:SCTK667A Series Place of Origin:China SCTK667A Series Split Core 100 to 1000A input CT, Current Transformers,Current sensor SCTK667A series retro-fit (split-core) current transformer has been specially designed to facilitate their installation in new or already existing net works. They may ... |
Shaanxi Shinhom Enterprise Co.,Ltd
Shaanxi |
![]() |
Brand Name:ZXY Model Number:ZXY-EI24 Place of Origin:Huizhou.China ... those operating at low frequencies. With its EI24 - sized core, it provides a stable and efficient magnetic path for current transformation. Leveraging the principle of electromagnetic induction, it accurately steps down high - current values in the |
Shenzhen Zhixiangyuan Electronics Co., Ltd.
|
![]() |
Brand Name:ZXY Model Number:ZXY-EI19 Place of Origin:China ...Current Transformer 1.Product Description The EI19 current transformer is an essential device in electrical systems, specializing in current measurement and protection. Its EI19 - sized core is engineered to offer a compact yet highly efficient solution. By leveraging the principle of electromagnetic induction, it accurately transforms high - current... |
Shenzhen Zhixiangyuan Electronics Co., Ltd.
|
![]() |
Brand Name:Dowis Model Number:EE10 Place of Origin:CN ... current and secondary current or primary current and ratio as per your requirements. For example if the energy meter is 5(80)A, you may need a current transformer with current to 80A or 100A. (2) Please specify the accuracy as per secondary circuit or |
Shenzhen Dowis Electronics Co.,Ltd
|
![]() |
Brand Name:Dowis Model Number:EE10 Place of Origin:CN ... current and secondary current or primary current and ratio as per your requirements. For example if the energy meter is 5(80)A, you may need a current transformer with current to 80A or 100A. (2) Please specify the accuracy as per secondary circuit or |
Shenzhen Dowis Electronics Co.,Ltd
|
![]() |
Brand Name:Chuangyin Model Number:CYR Place of Origin:ShenZhen ... terminals,S1,S2 secondary terminals P1&S1 same as P2,S2(subtractive polarity). 2. Technical Parameter 1) Rated Primary Current: 5-3000A; Rated Secondary Current: 5A, 1A 2). Rated voltage: |
Shenzhen Chuangyin Co., Ltd.
Guangdong |
![]() |
Brand Name:Chuangyin Model Number:CY-KKCT-15 Place of Origin:ShenZhen ...50/60Hz Sensor Split Core Current Transformer DC/AC Current Transformer Feature: Small size Low temperature drift, broad band Perfect reaction time Without the insertion loss, strong anti-jamming capability Current Overload Ability Application: Static ... |
Shenzhen Chuangyin Co., Ltd.
Guangdong |
![]() |
Brand Name:CY-Group Model Number:CY-RCT02 Place of Origin:China ...Current Transformer CY-RCT02 Clamp-on Rogowski Coil Current Transfomers The”RCT02 Clamp-on Flexible Rogowski coil current transformer” are designed for easy installed in tight spaces and without the need for dismantling the primary busbar or cables. Feature: .Display LCD measured parameters .Flexible and light weights appearance .Easy & quick installation in tight spaces .Excellent linearity .Maximum measuring current... |
Shenzhen Chuangyin Co., Ltd.
Guangdong |
![]() |
Brand Name:Chuangyin Model Number:LZZBW-12; LZZBW-17.5 Place of Origin:ShenZhen 17.5kV Medium Current Transformer Single-Phase Epoxy Resin Type Outdoor For Metering Current Usage Multi-Winding Epoxy Resin Casting 1.Product Introduction: LZZBW-12(17.5) current transformer Adopts outdoor resin casting and belongs to support type full... |
Shenzhen Chuangyin Co., Ltd.
Guangdong |
![]() |
Brand Name:YOMIN Model Number:LMZ1-0.5 Place of Origin:ZHEJAING, CHINA ...current transformer low voltage 5A for ct operated meter Production Description: LV indoor current transformer LMZ1-0.5 epoxy cast resin type . Indoor type current ratio:5-300/5A rated voltage :0.5kv or below 1).accuracy class: 0.2 , 0.5 , 1 , 3 2).buden :5VA----50VA 3).50/60Hz 4).standard :IEC . 5).ISO Certificate Specification: 1.Primary current 1~1000A 2.Secondary current... |
YUEQING YOMIN ELECTRIC CO., LTD
Zhejiang |
![]() |
Brand Name:GFUVE Model Number:LZCK-55-3 Place of Origin:BEIJING CHINA ...Current Transformer for power meter Introduction Overview The current transformer, the product complies with IEC 60044-1 IEC61869-2 Current Transformer"; for outdoor use rated voltage of 10kV and below. For circuit control, protection and other purposes. II. Structure Introduction The current transformer with high strength PVC shell, all cast bus structure. Transformer... |
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing |
![]() |
Brand Name:GFUVE Model Number:Q8A-2-1 Place of Origin:China ...Current Transformer 5A high precision for Oscilloscope Current Monitoring The model Q8A2 permalloy core 5A Clamp On Current Transformer with high accuracy up to 0.1% has been designed for use with multimeters, recorders, power analysers, safety testers etc. Clamp-on CT's & Flexible AC Current Probe; Split Core CT's ( AAC to AAC ) / (AAC to AAC) Flexible Current Transformer (FCT Series) Clamp-On Current Transformer... |
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing |
![]() |
Brand Name:GFUVE Model Number:LZCG530-10-100 Place of Origin:China ...endure input current ranging from 50A to 100A. If the monitored circuit malfunctions, it can output zero phase current which is 500 times smaller than the input current with the suggested 500 turns ratio so that the power supply is cut off to protect the |
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing |
![]() |
Brand Name:HNMC Model Number:KH150 Place of Origin:China ... 1VA(1Aoutput),5VA(5A output), 4Ω (mA output) Installation Suspension Output Lead output Outdoor Split-core Current Transformer Application - Utility pole probe monitoring & |
Zhengzhou Great Electric Co.,Ltd.
Henan |
![]() |
Brand Name:HNMC Model Number:KH150 Place of Origin:China ... 1VA(1Aoutput),5VA(5A output), 4Ω (mA output) Installation Suspension Output Lead output Outdoor Split-core Current Transformer Application - Utility pole probe monitoring & |
Zhengzhou Great Electric Co.,Ltd.
Henan |
![]() |
Brand Name:Shenzhen Chuangyin Co.,Ltd. Model Number:CY-KCT01 Place of Origin:China We are manufacturer for Instrument Transformer. Current transformer Split Core Current Transformers Open type CT CY-KCT01 (50~300A) Description: *50~300A *Indoor *Dry type / Epoxy resin ... |
Shenzhen Chuangyin Co., Ltd.
Guangdong |
![]() |
Brand Name:Acrel Model Number:AKH-0.66/K Place of Origin:China ... Technical parameter ADL100-EY Voltage Reference voltage 3*220/380V Reference frequency 50Hz Consumption <4VA(Each phase) Current Input Current 1(6)A,10(80)A Starting Current Connect directly: 0.004 Ib, connect via |
Jiangsu Acrel Electrical Manufacturing Co., LTD.
Jiangsu |
![]() |
Brand Name:Acrel Model Number:AKH-0.66/I Place of Origin:China ... Technical parameter ADL100-EY Voltage Reference voltage 3*220/380V Reference frequency 50Hz Consumption <4VA(Each phase) Current Input Current 1(6)A,10(80)A Starting Current Connect directly: 0.004 Ib, connect via |
Jiangsu Acrel Electrical Manufacturing Co., LTD.
Jiangsu |
![]() |
Brand Name:GFUVE Model Number:LZCK-55 Place of Origin:BEIJING CHINA ... or current levels. The most common usage of current transformers is to operate instruments or metering from high voltage or high current circuits, safely isolating secondary control circuitry from the high voltages or currents. The primary winding of |
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing |
![]() |
Brand Name:GFUVE Model Number:GFLZZ0956-10C4 Place of Origin:BEIJING CHINA ...Current Transformer Measurement Instrument The current transformer of the type GFLZZ0956-10C4 is casting resins and fully enclosed . It is used for metering electric energy and current , relay protection in the electrical system up to rated frequency 50Hz of 60Hz . The current instrument transformers can be executed according to the standards IEC60044-1 , IEC61869-2 and ANSI/IEEE C57.13 . Rated primary current... |
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing |