Model: | PD-132 |
Supply voltage: | AC110V or 220V,DC12V or 24V |
Power Consumption: | 4.5VA |
VOutput relays: | 240V/5A |
sensitivity: | 4 levels |
Company Info. |
SHENZHEN SINOMATIC TECHNOLOGY CO., LIMITED |
Verified Supplier |
View Contact Details |
Product List |
Parking boom barrier accessory car vehicle detector with conductive loop
ADVANTAGE FEATURES
* The pulse relay can be configured to activate the detection of
the vehicle or when the vehicle leaves the loop.
* This characteristic determines the non-detection level at maximum
sensitivity to avoid detecting vehicles such as large trucks.
* Sensitivity can be changed using four sensitivity settings on the
switch.
Our Advantages
1. Single Channel/Dual Channel available
2. 1 Year Standard Warranty, excellent after-sales service
3. 24h*7d at your service to give you best support
4. Detailed installation manual and wiring diagram to make
everything be easy
5. Fast finishing time for you to become more competitive at your
local market :3-5 days for small order.
FUNCTION AND FEATURES
1) Reset Switch : The reset switch enables the detector to be
manually reset during commissioning and testing . This results in
the detector re-tuning the sensing loop and becoming ready for
vehicle detection ;
2) Selectable Pulse Time : This feature sets the length of time
that the pulse relay will be energized for 1 Second or 0.5 Seconds
;
3) Pulse Relay Selection : The Pulse Relay may be configured to
energize on detection of a vehicle or when the vehicle leaves the
loop ;
4) Sensitivity Boost : This feature sets the undetect level to
maximum sensitivity and is used to prevent loss of detection of
high-bed vehicles ;
5) Switch Selectable Sensibility : 4 sensitivity setting are
available on the switches to allow flexibility in configuration ;
6) Switch Selectable Frequency : 4 frequency settings are available
to prevent cross-talk between adjacent loops ;
7) Filter Option : This option is used to provide a delay between
detection of the vehicle and switchiing of the output relay . This
relay is normally used to prevent false detection of small or fast
moving objects ;
8) Permanent Presence Option : This feature ensure detection of the
vehicle will be maintained when the vehicle is parked over the loop
for extended periods .
![]() |